


Proven leak detection for point-to-point pipelines.
Proven leak detection for point-to-point pipelines.
Proven leak detection for point-to-point pipelines.
Detect and localize leaks in minutes. Cutting spill costs, downtime, and compliance risk while keeping every line audit-ready.
Detect and localize leaks in minutes. Cutting spill costs, downtime, and compliance risk while keeping every line audit-ready.


Even straightforward pipelines can create complex detection challenges.
Even straightforward pipelines can create complex detection challenges.
Even straightforward pipelines can create complex detection challenges.
01
Small leaks can go undetected for hours with line-balance systems.
01
Small leaks can go undetected for hours with line-balance systems.
01
Small leaks can go undetected for hours with line-balance systems.
02
Frequent false alarms create fatigue and slow real response.
02
Frequent false alarms create fatigue and slow real response.
02
Frequent false alarms create fatigue and slow real response.
03
Intermittent or variable flow makes small leaks hard to spot in real time.
03
Intermittent or variable flow makes small leaks hard to spot in real time.
03
Intermittent or variable flow makes small leaks hard to spot in real time.
Pipewise delivers intelligent, layered detection.
Pipewise delivers intelligent, layered detection.
Pipewise delivers intelligent, layered detection.
Pipewise fuses real-time modeling, statistical analytics, and adaptive intelligence for rapid and reliable leak detection on point to point pipelines.
Pipewise fuses real-time modeling, statistical analytics, and adaptive intelligence for rapid and reliable leak detection on point to point pipelines.
Pipewise fuses real-time modeling, statistical analytics, and adaptive intelligence for rapid and reliable leak detection on point to point pipelines.
Core monitoring
Always-on Computational Pipeline Monitoring (CPM) compensated volume balance, forms the detection foundation.
3-4 weeks

Core monitoring
01
Core monitoring
Always-on Computational Pipeline Monitoring (CPM) compensated volume balance, forms the detection foundation.
3-4 weeks

Core monitoring
01
Core monitoring
Always-on Computational Pipeline Monitoring (CPM) compensated volume balance, forms the detection foundation.
3-4 weeks

Core monitoring
01
Statistical + transient filtering
Advanced analytics separate leaks from noise and estimates leak location.
3-4 weeks

Statistical + transient filtering
02
Statistical + transient filtering
Advanced analytics separate leaks from noise and estimates leak location.
3-4 weeks

Statistical + transient filtering
02
Statistical + transient filtering
Advanced analytics separate leaks from noise and estimates leak location.
3-4 weeks

Statistical + transient filtering
02
Specialized reliability modes
Ensures detection during shutdowns, startups, flow rate changes, and other transient events.
3-4 weeks

Specialized reliability modes
03
Specialized reliability modes
Ensures detection during shutdowns, startups, flow rate changes, and other transient events.
3-4 weeks

Specialized reliability modes
03
Specialized reliability modes
Ensures detection during shutdowns, startups, flow rate changes, and other transient events.
3-4 weeks

Specialized reliability modes
03
Adaptive intelligence
Machine learning anticipates leak behavior, improving speed, accuracy, and confidence.
3-4 weeks

Adaptive intelligence
04
Adaptive intelligence
Machine learning anticipates leak behavior, improving speed, accuracy, and confidence.
3-4 weeks

Adaptive intelligence
04
Adaptive intelligence
Machine learning anticipates leak behavior, improving speed, accuracy, and confidence.
3-4 weeks

Adaptive intelligence
04



Complete confidence, from detection to compliance.
Pipewise transforms your point-to-point pipelines into confidently monitored assets — delivering proven performance, trusted reliability, and full compliance assurance.

Detect and localize pinhole leaks in minutes.
Detects leaks as small as 0.5% of flow and localizes within 1-3% of total pipeline length.

Detect and localize pinhole leaks in minutes.
Detects leaks as small as 0.5% of flow and localizes within 1-3% of total pipeline length.

Detect and localize pinhole leaks in minutes.
Detects leaks as small as 0.5% of flow and localizes within 1-3% of total pipeline length.

Reliable alarms for real confidence.
Fewer than 2 false alarms a month — cutting operator fatigue and boosting confidence.

Reliable alarms for real confidence.
Fewer than 2 false alarms a month — cutting operator fatigue and boosting confidence.

Reliable alarms for real confidence.
Fewer than 2 false alarms a month — cutting operator fatigue and boosting confidence.

Detects across flexible instrumentation.
Supports flow-only, pressure-only, or combined inputs for leak detection and localization.

Detects across flexible instrumentation.
Supports flow-only, pressure-only, or combined inputs for leak detection and localization.

Detects across flexible instrumentation.
Supports flow-only, pressure-only, or combined inputs for leak detection and localization.

Stay inspection-ready, always.
Aligned with API RP 1130/1175, CSA Z662 Annex E, and PHMSA 49 CFR 195.

Stay inspection-ready, always.
Aligned with API RP 1130/1175, CSA Z662 Annex E, and PHMSA 49 CFR 195.

Stay inspection-ready, always.
Aligned with API RP 1130/1175, CSA Z662 Annex E, and PHMSA 49 CFR 195.
Consistent performance means reliable, stress-free operations.
Consistent performance means reliable, stress-free operations.
'Down to' detection rate (flow)
'Down to' detection rate (flow)
'Down to' detection rate (flow)
Average time to detection (min)
Average time to detection (min)
Average time to detection (min)
Leak localization (% of pipeline length)
Leak localization (% of pipeline length)
Leak localization (% of pipeline length)
Number of false alarms per month
Number of false alarms per month
Number of false alarms per month

Pipewise is more than leak detection.
Our intelligent monitoring tools optimize DRA, manage slack flow and wax buildup, and keep pigging operations safe and efficient.

Pipewise is more than leak detection.
Our intelligent monitoring tools optimize DRA, manage slack flow and wax buildup, and keep pigging operations safe and efficient.

Pipewise is more than leak detection.
Our intelligent monitoring tools optimize DRA, manage slack flow and wax buildup, and keep pigging operations safe and efficient.

Expert and prompt support, 24/7.
Our team performs continual system checks, tuning, and troubleshooting to ensure peak performance.

Expert and prompt support, 24/7.
Our team performs continual system checks, tuning, and troubleshooting to ensure peak performance.

Expert and prompt support, 24/7.
Our team performs continual system checks, tuning, and troubleshooting to ensure peak performance.

Operational Assurance Consulting
From leak detection audits to compliance readiness and meter/DAQ optimization, Pipewise provides vendor-neutral guidance to strengthen system integrity, performance, and audit readiness.

Operational Assurance Consulting
From leak detection audits to compliance readiness and meter/DAQ optimization, Pipewise provides vendor-neutral guidance to strengthen system integrity, performance, and audit readiness.

Operational Assurance Consulting
From leak detection audits to compliance readiness and meter/DAQ optimization, Pipewise provides vendor-neutral guidance to strengthen system integrity, performance, and audit readiness.
What would a leak cost on your pipeline?
What would a leak cost on your pipeline?
What would a leak cost on your pipeline?
Get a personalized assessment showing how improving detection speed prevents costly spills and compliance issues.
Get a personalized assessment showing how improving detection speed prevents costly spills and compliance issues.
FAQs
FAQs
FAQs
Here’s what you need to know about our Point-to-point leak detection offering.
VBx is designed to detect small, developing leaks, typically down to ~0.5% of flow, even when meter uncertainty is higher than the leak size. This is achieved through statistical evidence accumulation rather than fixed thresholds, allowing VBx to identify sustained loss patterns that traditional line balance systems miss or detect too late.
On point-to-point pipelines with suitable instrumentation, VBx can typically localize a confirmed leak to within 1–2 miles (2–3 km). Localization accuracy depends on pipeline length, meter placement, data quality, and operating conditions, and is intended to narrow response and inspection scope, not replace field verification.
VBx is flexible by design and can operate with: Flow-only data; Pressure-only data; Combined flow and pressure data. The system adapts its detection logic to the available instrumentation, making it suitable for both well- instrumented pipelines and assets with limited or imperfect data.
VBx is built for non-steady-state operation. Transient-aware filtering and specialized reliability modes allow the system to remain stable during pump cycling, startups, shutdowns, and batching. Reducing false alarms while maintaining sensitivity to real leaks.
VBx performance depends on the quality and placement of available instrumentation. While it can operate with limited data, very sparse or unreliable measurements may affect detection speed or localization resolution. During discovery, Pipewise reviews instrumentation, operations, and data quality to set realistic performance expectations and determine whether VBx alone, or a complementary method, is the best fit.
VBx is designed to detect small, developing leaks, typically down to ~0.5% of flow, even when meter uncertainty is higher than the leak size. This is achieved through statistical evidence accumulation rather than fixed thresholds, allowing VBx to identify sustained loss patterns that traditional line balance systems miss or detect too late.
On point-to-point pipelines with suitable instrumentation, VBx can typically localize a confirmed leak to within 1–2 miles (2–3 km). Localization accuracy depends on pipeline length, meter placement, data quality, and operating conditions, and is intended to narrow response and inspection scope, not replace field verification.
VBx is flexible by design and can operate with: Flow-only data; Pressure-only data; Combined flow and pressure data. The system adapts its detection logic to the available instrumentation, making it suitable for both well- instrumented pipelines and assets with limited or imperfect data.
VBx is built for non-steady-state operation. Transient-aware filtering and specialized reliability modes allow the system to remain stable during pump cycling, startups, shutdowns, and batching. Reducing false alarms while maintaining sensitivity to real leaks.
VBx performance depends on the quality and placement of available instrumentation. While it can operate with limited data, very sparse or unreliable measurements may affect detection speed or localization resolution. During discovery, Pipewise reviews instrumentation, operations, and data quality to set realistic performance expectations and determine whether VBx alone, or a complementary method, is the best fit.
VBx is designed to detect small, developing leaks, typically down to ~0.5% of flow, even when meter uncertainty is higher than the leak size. This is achieved through statistical evidence accumulation rather than fixed thresholds, allowing VBx to identify sustained loss patterns that traditional line balance systems miss or detect too late.
On point-to-point pipelines with suitable instrumentation, VBx can typically localize a confirmed leak to within 1–2 miles (2–3 km). Localization accuracy depends on pipeline length, meter placement, data quality, and operating conditions, and is intended to narrow response and inspection scope, not replace field verification.
VBx is flexible by design and can operate with: Flow-only data; Pressure-only data; Combined flow and pressure data. The system adapts its detection logic to the available instrumentation, making it suitable for both well- instrumented pipelines and assets with limited or imperfect data.
VBx is built for non-steady-state operation. Transient-aware filtering and specialized reliability modes allow the system to remain stable during pump cycling, startups, shutdowns, and batching. Reducing false alarms while maintaining sensitivity to real leaks.
VBx performance depends on the quality and placement of available instrumentation. While it can operate with limited data, very sparse or unreliable measurements may affect detection speed or localization resolution. During discovery, Pipewise reviews instrumentation, operations, and data quality to set realistic performance expectations and determine whether VBx alone, or a complementary method, is the best fit.
Upgrade your leak detection, without replacing your system.
Move beyond slow, reactive line-balance detection. With Pipewise, you get rapid detection, fewer false alarms, and proven compliance, all using your existing data infrastructure.

Upgrade your leak detection, without replacing your system.
Move beyond slow, reactive line-balance detection. With Pipewise, you get rapid detection, fewer false alarms, and proven compliance, all using your existing data infrastructure.

Upgrade your leak detection, without replacing your system.
Move beyond slow, reactive line-balance detection. With Pipewise, you get rapid detection, fewer false alarms, and proven compliance, all using your existing data infrastructure.



